Current version50 projects to build and fault-find, with hidden faults on Easy or Hard — plus motors that turn, timers with a COM terminal, drives with real 24V inputs, logic on the custom PCB, side panels you can hide, and fixes for timers, transformers and drawings.
New
- 50 Projects: a series of control circuits to build and fault-find, from a two-hand control to a PLC mixing tank, with five big Challenge projects at the end, three of them over 40 parts. Open any project working, or pick Easy (one hidden fault) or Hard (three, on different parts) — the faults are different every time. Open it from Presets → 50 Projects & fault finding.
- Fault-finding panel. An Easy or Hard project opens with a panel: operate the circuit, use the meter, then press Check answer and click the part or wire you think has failed. On Hard you have to find every fault, the way you would on a real job; each one you find is replaced, so the symptoms can change as you go. Reveal shows the answer, and Share this fault sends the same circuit and faults to someone else.
- Projects you’ve fault-found are ticked on the 50 Projects page, with a count of how many you’ve done.
- More faults to inject. Timers can have an open coil, a contact stuck at rest or a welded contact. Breakers can have their contacts open, fail to trip (so the protection upstream has to clear the fault), or lose one pole of a 3-pole MCB and single-phase a motor. A Load can be partly shorted (trips after a while) or shorted (trips straight away). Two wiring mistakes can be injected too: NO and NC wires swapped on a pushbutton, contact or timer (T1 and T2 on a 3-position selector), and two phases swapped on a motor, so it runs the wrong way. A wire can have a loose connection that drops out every few seconds, and an overload can have its 95-96 trip contact open without tripping, or be set too low so it trips after the motor has run for a while. The Easy and Hard faults in 25 of the 50 Projects now include them.
- Current flow on / off. Tools → Current Flow hides the glow and the moving dashes on live wires, so the canvas doesn’t give the fault away: find the live wires with the meter, as you would on a real panel. Lamps, coils and motors still show what they’re doing, and your choice is remembered. Hard projects always run with it off, until you’ve found every fault or pressed Reveal.
- Settings at a glance. The Circuit Status panel now shows what’s on or off: current flow, faults shown, the meter, wire numbers and the drawing symbols. Click a line to change it.
- Motors turn. While you simulate, a running motor’s shaft spins: it runs up when started, follows the drive’s speed, and coasts down when it’s switched off, in the direction its arrow shows.
- Timers have a COM terminal. TON and TOF timers now have a changeover contact like a real timing relay: wire your supply to COM, and COM–NC is closed at rest while COM–NO closes when the timer operates. As on a real timer, the contact needs a supply on COM: every preset and project has COM wired, and a circuit saved earlier with nothing on COM tells you when it opens.
- Drives have a +24V terminal. A drive’s control inputs (DI1–DI3) are 24V DC, as on a real drive. Feed your buttons from the drive’s own +24V terminal; COM is its 0V, or the place to connect an external 24V supply’s 0V. The VFD and PLC + VFD presets and projects 37 and 38 are wired this way.
- Logic on the custom PCB. Give each output a rule: AND, OR, XOR, NAND, NOR and NOT, an on-delay (AFTER 3), or compare an input’s voltage with > < >= <= == — for example LOW = SUPPLY < 200 AFTER 2. The block now looks like a circuit board, with tracks to its terminals.
- PLC editor light mode: the ☀ button in the ladder editor switches to a white sheet with dark ink, keeping the grid. It’s remembered on your device.
- Hide or resize the side panels: the tab on each panel’s edge hides it, and dragging the edge resizes it. Your layout is remembered.
- Launch tips: a short tip each time you open PickettPanel. Switch them off from the tip itself.
- Drawing colours: PDF drawings are now black by default, as professional drawings are. Pick Colour in the export window to keep the training colours; your choice is remembered.
Improved
- Works by touch on tablets. Press and hold START, RESET or any push button with your finger and it stays pressed until you let go, the same as with a mouse. Drag empty space to move around the drawing, pinch to zoom, and tap a part in the parts panel to add it. On a phone, PickettPanel now says it’s made for a bigger screen and offers to send you the link, or you can try it anyway with the side panels hidden.
- Protection is always on. A short circuit now always trips the fuse or breaker in its path, and only that one: of the devices the short flows through, the lowest-rated operates first. With no fuse or breaker in the path, the supply’s own breaker trips. Strict Mode has gone from the Tools menu, because it’s now how every circuit behaves.
- Mains on a drive input trips the drive. Put 230V on DI1–DI3 and the drive faults with FLT DI and explains why: on a real drive it would destroy the input card. A circuit saved before this version that feeds a drive’s inputs from the mains supply tells you so when it opens: move those wires to the drive’s +24V.
- Wires line up. The 3-phase supply, 3-pole MCB, overload, motor and drive now all space their phase terminals the same distance apart, so parts placed in line wire up dead straight.
- Help → Parts Guide: what every part in the left-hand panel does, its terminals and how to set it up — starting with how to make a contactor or relay from a coil and its linked contacts.
- Meter on / off. The DM-10 has a ⏻ button: switch it off and the leads stay clipped on while you wire and edit as normal, then switch it back on to read. No more closing and reopening it.
- The 3-pole MCB, 3-position selector, control transformer and motor now change to IEC or ANSI symbols with everything else.
- The drawing uses your tags. A part you’ve tagged (QF1, KM1, FU1, OL1, KT1…) keeps that tag on the PDF drawing, so it matches the canvas; it used to be renumbered (QF1 became Q1, OL1 became F2). Devices are numbered as you drop them (KM1, KM2, QF1…), and parts with a name instead of a tag (START, RUN) still get a designator on the drawing.
- A contactor’s contacts only link to a contactor, and a relay’s contacts only to a relay. Validate Circuit flags an older circuit that mixes them.
- The single-pole breaker is now called an MCB, like the 3-pole one.
- Drawings leave nothing out silently. Loads wired in series are drawn on one rung, a circuit fed from a control transformer gets its own sheet with X1 / X2 as the rails, a feed taken from a coil’s A1 through a contact is drawn, and anything that still can’t be drawn (like contacts straight from L1 to N) is listed under Drawing notes.
- Easier to select wires. A click right on a wire picks it, even where it runs beside a part; where wires share a line, click again for the next one. Clicking a selected wire no longer leaves a stray bend.
- Contactor terminal markings. Main poles show 1/L1–2/T1, 3/L2–4/T2, 5/L3–6/T3, as printed on a real contactor, and contacts show their numbers (13–14, 21–22…) on the canvas as well as on the drawing. A contact becomes a main pole once it’s wired into the power circuit, or double-click it and type 1, 2 or 3 to set it yourself.
- A small, faint PickettPanel mark sits in the bottom-left corner of the canvas (behind your circuit), and PDF drawings say “Drawn with PickettPanel” in the title block. Circuits and drawings you make are still yours.
- To link a contact to a coil, double-click the contact and type the coil’s name (KM1, K2…), instead of its internal ID.
- Help → Drives & Motors explains the drive’s 24V inputs, +24V and COM, and the new FLT DI fault code.
- The fault-finding challenges now live in the 50 Projects: the 14 challenges are the Guided option on their six circuits (Start/Stop, Indicators, On-Delay Timer, DOL, Forward / Reverse and VFD). Challenge links you’ve shared still work, and your progress carries over. The Challenges button has gone from the top bar.
- The Presets menu now lists the 10 core circuits; the rest are in the 50 Projects. Circuits you’ve saved and links you’ve shared still open as before.
- Help → Fault Finding now explains the 50 Projects: Easy, Hard and Guided, and how the fault-finding panel works.
- In the PLC window, inputs are on the left and outputs on the right, like a real I/O layout.
- A circuit that contains parts this version doesn’t have now opens with those parts left out, and tells you so, instead of failing to load.
Fixed
- Off-delay timers no longer switch on by themselves. An off-delay timer that had never been energised turned its output on as soon as you started simulating, so a stair light or a fan run-on started on. Its output now only comes on once the timer has been energised.
- An off-delay timer’s NC contact now works. Wired from COM, it’s closed at rest, opens as soon as the timer is energised, and closes again once the off-delay has run out.
- Loads fed from a control transformer whose secondary is earthed (X2 linked to PE) now work. Earthing the secondary used to cut them off.
- A relay or lamp switched by a timer that is itself driven from another timer’s output now switches when it should.
- Single-phase PDF drawings now show the return as N, never PE, and a circuit fed from a 3-phase supply is labelled L1 230V and N.